recovery of water from boiler flue gas

Product thermal capacity: 4-35 t/h
Working pressure: 1.0-2.5 MPA
Outlet temperature:: 184-350 ℃
Available fuel: Bituminous coal, lean coal, anthracite
Available industries: Heating, chemical, food, tobacco, textile, print and dyeing, feed, medicine, building materials, wine, hospital

Use Feedwater Economizers for Waste Heat Recove

2017-6-3 · Use Feedwater Economizers for Waste Heat Recovery A feedwater economizer reduces steam boiler fuel requirements by transferring heat from the flue gas to incoming feedwater. Boiler flue gases are often rejected to the stack at temperatures more than 100°F to 150°F higher than the temperature of the generated steam. Generally, boiler

Get A Quote

Recovery of water from boiler flue gas - Lehigh Preserve

Cited by: 19

Recovery of Water from Boiler Flue Gas Using

Cited by: 192019-5-19 · @article{osti_1084027, title = {Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers}, author = {Levy, Edward and Bilirgen, Harun and DuPont, John}, abstractNote = {Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling.

Get A Quote

Recovery of Water from Boiler Flue Gas (Technical …

Cited by: 19

Recovery of water from boiler flue gas | Request P

Cited by: 19One of the methods of water recovery was investigated by Shen et al. [22], as it presented membrane technology as a potential means for water recovery from the flue gas of a lignite boiler.

Get A Quote

New Technology Will Recover Heat &Water from Flue

For a coal‐fired power plant boiler equipped with a wet FGD unit, flue gas exits at up to about 180 °F, with nearly 100 percent relative humidity. Flue Gas Water and Heat Recovery with a

Get A Quote

RECOVERY OF WATER FROM BOILER FLUE GAS USING …

Cited by: 3

Waste heat and water recovery from natural gas …

Cited by: 3

IWC-08-17 Flue Gas Condensate and Energy Recovery as

Cited by: 3Cited by: 32011-8-8 · which transfers heat from the flue gas to a portion of the boiler feed water, preheating it from 40 to 65°C (104 to 149°F). The cooling stage is the heart of the Karlskoga energy recovery system, reclaiming up to 20 MW-h from the hot flue gas. It also condenses the water vapor contained by the flue gas, producing liquid water used as makeup

Get A Quote
Contact us
Tel

0086-510-68530066

Chat online

Online message


Gas-fired(oil-fired) boilers
Coal-fired boilers
Biomass-fired boilers
Thermal oil heaters
Hot water:0.7-14 MW
14.1-21 MW
21.1-29 MW
29.1-75 MW
Steam :  1-10 t/h
11-20 t/h
21-90 t/h
91-140 t/h