Product thermal capacity: | 4-35 t/h |
Working pressure: | 1.0-2.5 MPA |
Outlet temperature:: | 184-350 ℃ |
Available fuel: | Bituminous coal, lean coal, anthracite |
Available industries: | Heating, chemical, food, tobacco, textile, print and dyeing, feed, medicine, building materials, wine, hospital |
2018-3-1 · Inserting high-pressure condensate into a low-pressure, pumped condensate-return line can cause waterhammer. Understand why and avoid it Figure 1. The rupture of this check valve from a steam trap assembly allowed the condensate system to drain over 600 ft3 of condensate over a long weekend into a steam vault, completely flooding it 1.
Get A Quote2017-6-13 · the condensate return pressure is systematically controlled to a predetermined set point which is matched to the process peak performance level. There are four classifications of a condensate system used in plants today. 1. Gravity or atmospheric (condensate line pressure maintained at or close to zero psi) 2. Low pressure (1 to 15 psi) 3.
Get A Quote2018-11-7 · The role of steam distribution lines is to reliably supply steam of the highest reasonable quality to the steam-using equipment. In order for this to be achieved, condensate must be removed quickly and efficiently through steam traps installed in proper condensate …
Get A QuoteLower steam pressure gives better temperature control. The Effect of Steam Pressure on Flash Steam. Most condensate return systems are vented. There are condensate return systems, similar to the Kadant Liqui-Mover® condensate pumps we represent, which are closed—but in …
Get A Quote2018-11-9 · Vented vs. Pressurized Condensate Recovery. In a vented condensate recovery system, steam trap inlet pressure or a condensate pump is used to return condensate to an open-to-atmosphere collection tank for use as boiler make-up water, pre-heat or other hot water applications.
Get A Quote2018-8-5 · condensate return/water piping system, and a steam-use facility (Figure 1). In this section, the discussion is focused on the integration of the various equipment within
Get A Quote2011-5-10 · The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum quantity of condensate to the boiler plant. There are several factors that impact the reliability, performance, longevity, and maintenance requirements for the condensate piping system. Some of these factors are listed below: Condensate […]
Get A QuoteTHE BOILER HOUSE - A BASIC OVERVIEW OF A STEAM SYSTEM -2006-12-6 · Pipe Sizing Steam Supply and Condensate Return Lines Definitions system. The total pressure drop in the system should not exceed 20% of the very low pressure differential between trap and condensate return pipe, trap discharge lines can be increased one pipe size advantageously.
Get A Quote2015-9-30 · PRESSURIZED CONDENSATE RETURN SYSTEMS NOT A NEW CONCEPT, BUT A CONCEPT TO BE ADDRESSED TODAY DUE TO THE INCREASINGLY HIGH ENERGY COSTS IN STEAM SYSTEM OPERATIONS BY Kelly Paffel Technical Manager Plant Support & Evaluations, Inc 920-965-0114 [email protected]
Get A QuotePrivacy policy
© ZOZEN boiler Co., Ltd.. All rights reserved.